Fat-soluble vitamins
Designed to deliver reliable chromatographic performance and help laboratories select the most suitable stationary phase for their analytical applications.
Develosil C30 columns provide extended alkyl selectivity useful for carotenoids, geometric isomers, fat-soluble vitamins, lipids, triglycerides and highly hydrophobic compounds.
Develosil C30 columns provide extended alkyl selectivity useful for carotenoids, geometric isomers, fat-soluble vitamins, lipids, triglycerides and highly hydrophobic compounds.
Develosil stationary phases are offered in multiple particle sizes and column dimensions to support analytical, semi-micro, guard, semi-preparative and preparative workflows. Review the specifications below to compare the configurations available for this family.
Analytical, Guard, Preparative, Semi Micro, Semi Preparative
49 listed records

Develosil C30 Columns provide enhanced hydrophobic interactions for carotenoids, lipids, vitamins and geometric isomer separations. Designed to deliver reliable chromatographic performance and help laboratories select the most suitable stationary phase for their analytical applications. Designed to deliver reliable chromatographic performance and help laboratories select the most suitable stationary phase for their analytical applications.Fat-soluble vitamins
Enhanced shape selectivity versus conventional C18
Assay, impurity profiling and stability-indicating method development.
ExploreSelectivity screening for complex matrices and hydrophobic or polar targets.
ExploreRoutine monitoring, exploratory separations and method optimization.
ExploreChoose aqueous-organic systems, modifiers and pH only within analyte, silica and detector compatibility. For RPAQUEOUS, water-rich operation is a key selection consideration.
Filter samples, control particulate loading, avoid buffer precipitation, monitor pressure and use a compatible guard solution.
Match chemistry, dimensions, particle size and selectivity goals rather than replacing by brand name alone.
| Product Name | Particle Size | Dimensions | Catalog Number | Configuration |
|---|---|---|---|---|
| C30-UG, 5μm | 5 µm | 2.0 × 100 mm | UG17520100W | Semi Micro |
| C30-UG, 5μm | 5 µm | 2.0 × 150 mm | UG17520150W | Semi Micro |
| C30-UG, 5μm | 5 µm | 2.0 × 250 mm | UG17520250W | Semi Micro |
| C30-UG, 5μm | 5 µm | 3.0 × 150 mm | UG17530150W | Analytical |
| C30-UG, 5μm | 5 µm | 4.0 × 35 mm | UG17540035W | Analytical |
| C30-UG, 5μm | 5 µm | 4.0 × 35 mm | UG175400356 | Analytical |
| C30-UG, 5μm | 5 µm | 4.0 × 250 mm | UG17540250W | Analytical |
| C30-UG, 5μm | 5 µm | 4.6 × 150 mm | UG17546150W | Analytical |
| C30-UG, 5μm | 5 µm | 4.6 × 250 mm | UG17546250W | Analytical |
| C30-UG, 5μm | 5 µm | 4.6 × 300 mm | UG17546300W | Analytical |
| C30-UG, 5μm | 5 µm | 8.0 × 250 mm | UG17580250W | Semi Preparative |
| C30-UG, 5μm | 5 µm | 10 × 250 mm | UG175P1250W | Semi Preparative |
| C30-UG, 5μm | 5 µm | 20 × 150 mm | UG175P2150W | Semi Preparative |
| C30-UG, 5μm | 5 µm | 20 × 250 mm | UG175P2250W | Semi Preparative |
| C30-UG, 5μm | 5 µm | 4.6 × 10 mm | UG17546010W | Guard |
| C30-UG, 5μm | 5 µm | 20 × 50 mm | UG175P2050WG | Semi Preparative |
| Develosil C30-UG-3 | 3 µm | 2.0 × 50 mm | UG17320050W | Semi Micro |
| Develosil C30-UG-3 | 3 µm | 2.0 × 100 mm | UG17320100W | Semi Micro |
| Develosil C30-UG-3 | 3 µm | 2.0 × 150 mm | UG17320150W | Semi Micro |
| Develosil C30-UG-3 | 3 µm | 2.0 × 250 mm | UG17320150W | Semi Micro |
| Develosil C30-UG-5 | 5 µm | 2.0 × 50 mm | UG17520050W | Semi Micro |
| Develosil C30-UG-5 | 5 µm | 2.0 × 100 mm | UG17520100W | Semi Micro |
| Develosil C30-UG-5 | 5 µm | 2.0 × 150 mm | UG17520150W | Semi Micro |
| Develosil C30-UG-5 | 5 µm | 2.0 × 250 mm | UG17520250W | Semi Micro |
| Develosil C30-UG-3 | 3 µm | 4.6 × 50 mm | UG17346050W | Analytical |
| Develosil C30-UG-3 | 3 µm | 4.6 × 100 mm | UG17346100W | Analytical |
| Develosil C30-UG-3 | 3 µm | 4.6 × 150 mm | UG17346150W | Analytical |
| Develosil C30-UG-3 | 3 µm | 4.6 × 250 mm | UG17346250W | Analytical |
| Develosil C30-UG-5 | 5 µm | 3.0 × 150 mm | UG17530150W | Analytical |
| Develosil C30-UG-5 | 5 µm | 3.0 × 250 mm | UG17530250W | Analytical |
| Develosil C30-UG-5 | 5 µm | 4.0 × 150 mm | UG17540150W | Analytical |
| Develosil C30-UG-5 | 5 µm | 4.0 × 250 mm | UG17540250W | Analytical |
| Develosil C30-UG-5 | 5 µm | 4.6 × 50 mm | UG17546050W | Analytical |
| Develosil C30-UG-5 | 5 µm | 4.6 × 100 mm | UG17546100W | Analytical |
| Develosil C30-UG-5 | 5 µm | 4.6 × 150 mm | UG17546150W | Analytical |
| Develosil C30-UG-5 | 5 µm | 4.6 × 250 mm | UG17546250W | Analytical |
| Develosil C30-UG-5 | 5 µm | 8.0 × 250 mm | UG17580250W | Semi Preparative |
| Develosil C30-UG-5 | 5 µm | 10.0 × 250 mm | UG175P1250W | Semi Preparative |
| Develosil C30-UG-5 | 5 µm | 20.0 × 250 mm | UG175P2250W | Semi Preparative |
| Develosil C30-UG-5 | 5 µm | 28.0 × 250 mm | UG175P3250W | Semi Preparative |
| Develosil C30-UG-10 | 10 µm | 20.0 × 250 mm | UG170P2250W | Semi Preparative |
| Develosil C30-UG-10 | 10 µm | 28.0 × 250 mm | UG170P3250W | Semi Preparative |
| Develosil C30-UG-5 | 5 µm | 8.0 × 10 mm | UG17580010W | Guard |
| Develosil C30-UG-5 | 5 µm | 20.0 × 50 mm | UG175P2050W | Semi Preparative |
| Develosil C30-UG-10 | 10 µm | 20.0 × 50 mm | UG170P2050W | Semi Preparative |
| Develosil C30-UG-15/30 | 15/30 µm | 20.0 × 50 mm | UG17BP2050W | Semi Preparative |
| Develosil C30-UG-10 | 10 µm | 50.0 × 300 mm | UG170P5300W | Preparative |
| Develosil C30-UG-10 | 10 µm | 50.0 × 500 mm | UG170P5500W | Preparative |
| Develosil C30-UG-10 | 10 µm | 50.0 × 100 mm | UG170P5100W | Preparative |
Develosil C30 columns provide extended alkyl selectivity useful for carotenoids, geometric isomers, fat-soluble vitamins, lipids, triglycerides and highly hydrophobic compounds.
Available particle sizes include 10 µm, 15/30 µm, 3 µm, 5 µm.
Available formats include Analytical, Guard, Preparative, Semi Micro, Semi Preparative. Please confirm current availability when requesting a quotation.
Use the storage solvent and shutdown procedure validated for the method and compatible with the stationary phase. Avoid buffer precipitation and record the final solvent composition.
Akira Analytical Solutions Pvt. Ltd. supplies and supports Develosil columns in India.
Send your current column, method conditions and target analytes.
C30 shape selectivity for carotenoids, vitamins, lipids and isomers.
View Technical Data