Manufacturer: Nomura Chemical Co., Ltd.India distributor: Akira Analytical Solutions Pvt. Ltd.

USP HPLC Packings – Develosil Columns

Use the USP L classifications below to compare stationary-phase chemistry, support method transfer and identify suitable Develosil column families.

Manufacturer

Nomura Chemical Co., Ltd.

Develosil chromatography columns are manufactured by Nomura Chemical Co., Ltd. The phases below are shown under their applicable USP L classifications to help laboratories compare chemistries and select suitable columns for method transfer.

USP reference

USP Listing Table

USP L Packing Develosil Column / Phase Stationary Phase Type USP Packing Description Manufacturer
L1 Develosil ODS C18 / ODS reversed phase Octadecylsilane chemically bonded to porous or non-porous silica or ceramic microparticles, generally 1.5–10 µm, or supplied as a monolithic rod. Nomura Chemical
L10 Develosil CN-UG Cyano (CN), reversed- or normal-phase use Nitrile groups chemically bonded to porous silica particles, generally 1.5–10 µm, or supplied as a monolithic silica rod. Nomura Chemical
L13 Develosil TMS-UG C1 C1 / trimethylsilane, low-retention reversed phase Trimethylsilane chemically bonded to porous silica particles, generally 3–10 µm. Nomura Chemical
L62 Develosil C30 C30, shape-selective reversed phase C30 silane bonded phase on fully porous spherical silica, generally 3–15 µm. Nomura Chemical
L62 Develosil C30-UG C30, UG series C30 silane bonded phase on fully porous spherical silica, generally 3–15 µm. Nomura Chemical
L62 Develosil RP-Aqueous Aqueous-compatible reversed phase C30 silane bonded phase on fully porous spherical silica, generally 3–15 µm. Nomura Chemical
L62 Develosil Combi-RP Hybrid-selectivity reversed phase C30 silane bonded phase on fully porous spherical silica, generally 3–15 µm. Nomura Chemical
L62 Develosil RP-Aqueous-AR Aqueous-compatible reversed phase, AR variant C30 silane bonded phase on fully porous spherical silica, generally 3–15 µm. Nomura Chemical
When transferring a USP method, match the USP chemistry first, then confirm particle size, internal diameter and column length against the method requirements.
Column selection guidance

What the USP Packings Mean for Develosil Selection

USP L1 – Develosil ODS

Chemistry: C18 / octadecylsilane bonded phase.

Develosil ODS is the standard reversed-phase starting point for routine assay, impurity profiling and stability testing. It provides strong hydrophobic retention and broad applicability across many compound classes.

  • Best suited for: General reversed-phase separations, pharmaceutical QC and stability studies
  • Method transfer: Match L1 chemistry before matching particle size and dimensions
  • Consider another phase when: More polar retention or different selectivity is required
View Develosil ODS Columns

USP L10 – Develosil CN-UG

Chemistry: Cyano / nitrile bonded phase.

Develosil CN-UG offers a useful selectivity change compared with C18. Depending on mobile-phase selection, it may be used in reversed-phase or normal-phase workflows and is useful when a medium-polarity surface is required.

  • Best suited for: Isomer separations, moderately polar analytes and orthogonal screening
  • Typical benefit: Different elution order compared with ODS
  • Method-development role: Alternative selectivity for aromatic and polar compounds

USP L13 – Develosil TMS-UG C1

Chemistry: C1 / trimethylsilane bonded phase.

Develosil TMS-UG C1 provides lower hydrophobic retention than C18. It is useful when strongly non-polar compounds are retained too long on conventional ODS columns or when shorter run times are required.

  • Best suited for: Faster analysis of non-polar compounds
  • Typical benefit: Reduced retention of highly hydrophobic analytes
  • Method-transfer role: A weaker reversed-phase alternative to C18

USP L62 – Develosil C30 Family and Related Phases

Chemistry: C30 bonded phase on fully porous spherical silica.

USP L62 phases provide enhanced shape selectivity and are particularly useful for carotenoids, lipid isomers and other geometrical or positional isomers where C18 may not offer sufficient resolution.

  • Develosil C30: Primary C30 option for isomeric separations
  • Develosil C30-UG: UG-series C30 option for reproducible performance
  • RP-Aqueous / RP-Aqueous-AR: Suitable for highly aqueous mobile phases and polar analytes
  • Combi-RP: Alternative reversed-phase selectivity for challenging matrices
Customer guidance

Frequently Asked Questions

Who manufactures Develosil columns?

Develosil chromatography columns are manufactured by Nomura Chemical Co., Ltd.

Which USP L packing applies to Develosil ODS?

Develosil ODS is classified under USP L1, the C18 / octadecylsilane bonded-phase category.

Which USP L packing applies to Develosil CN-UG?

Develosil CN-UG is classified under USP L10, the cyano / nitrile bonded-phase category.

Which USP L packing applies to Develosil TMS-UG C1?

Develosil TMS-UG C1 is classified under USP L13, the trimethylsilane / C1 bonded-phase category.

Which USP L packing applies to Develosil C30?

Develosil C30 and related C30 phases are classified under USP L62.

How should I choose an equivalent column for a USP method?

First match the USP L classification and stationary-phase chemistry. Then compare particle size, internal diameter, column length and method-specific operating conditions before final selection.

Need Help Selecting a USP-Equivalent Develosil Column?

Share the USP L classification, current column dimensions, particle size and application details with Akira Analytical Solutions Pvt. Ltd. for technical guidance.

Contact Technical Support